B&C Electronics BC 7687 Universal controller
The instrument is used when there is a need to add display
functions, control, alarm, and / or automatic cleaning of the
sensor to a transmitter capable of performing any type of
measurement.
The instrument provides:
- measuring display in the selectable range from -9999 to 9999, corresponding to the 0-20 mA or 4-20 mA input;
- Vdc power to power the 4-20 mA loop of the transmitter;
- automatic measurement control function
- alarm from the low/high measurement, the set point overtime operation and the logic input;
- programmable dual analog output for recording and acquisition of the measurement values or PID regulation;
- hold / alarm function activated by two external volt free contacts
- automatic /manual autoclean function.
This unit allows a differential measurement, by using two 0-20 mA or 4-20 mA transmitters featuring the same measurement scale.
FeaturesTechnical DataApplications
Specifications
- Display: multi-line graphic
- Input from: 0-20 or 4-20 mA single or differential
-
- Scale: – 9999 / +9999 with selectable decimal point
- Measuring unit: selectable and 4 digit configurable
- 2 set-point with min/max function, hysteresys and delay time programmable
- Analog output: 0-20 or 4-20 mA isolated for PID regulation or measure transmission
- Min/max alarm relay, activate/deactivate function selectable
- Parameters configuration on two levels with access code selected by the operator
- Two logic digital input for hold or alarm function, selectable
- Power supply: 85/264 Vac – 50/60 Hz, 5 VA
- Enclosure: metallic, IP 65 frontal protection
- Dimensions: 98x98x104 mm (90x90x95 mm back)
- Registered design: 002564666-003
Inputs: | 4-20 mA, 0-20 mA active or passive single or differentia |
Power supply for passive transmitters: | 24Vdc (50 mA max) |
Zero: | ± 10 % |
Sensitivity: | 12.5 % ÷ 250 % |
Resolution: | 1 digit |
Accuracy: | 0.2 % |
Repeatability: | 0.1 % |
Non-linearity: | 0.1 % |
Dual filter software: | 0.4 ÷ 50.0 seconds for small and large variations |
Dual analog output: | 0-20 mA / 4-20 mA Rmax 600 Ω |
Dual set points HI/LO: | ON/OFF – PID – PFM – PWM, SPST relays |
Hysteresis: | 0 ÷ 1.40 pH, 0 ÷ 200 mV |
Delay: | 0 ÷ 100.0 seconds |
Alarm: | SPDT relay with delay 0 ÷ 100.0 seconds |
Cleaning function: | off / autoclean / manual, relay SPDT repetition time 0.1 ÷ 100.0 hours cleaning time 1.0 ÷ 60.0 seconds holding time 0.0 ÷20.0 minutes |
SPST and SPDT relay contacts: | 220V – 5 A resistive load |
Operating temperature: | -10 ÷ 60 °C |
Humidity: | 95% without condensation |
Power supply: | 85 ÷ 264Vac – 50/60 Hz 9 ÷ 36Vdc, 12 ÷ 24Vac (option 091.42x |
Terminal blocks: | removable |
Weight: | 1360 g (BC 6587) 450 g (BC 7687) |
Enclosure: | ABS, IP 65 protection (BC 6587) Metallic, IP 65 front panel only (BC 7687) |
Dimensions: | 256x230x89 mm (BC 6587) 98x98x104 mm, 90x90x95 mm panel cutout (BC 7687) |
EMC/RFI conformity: | EN 61326 |
Registered design: | 002564666-002 (BC 6587) 002564666-003 (BC 7687) |
Applications BC 7687
- Aquaculture
- Drinking water
- Biotechnology
- Geology
- Food and beverage
- Paper and pulp
- Chemical industry
- Pharmaceutical
- Electroplating
- Printing industry
- Textile industry
- Fertirrigation
- Underground water
- Environmental monitoring
- Swimming pools
- Security
- Water treatment
- Surfaces treatment
- University and research