B&C Electronics BC 6587 Universal controller – transmitter
The BC 6587 and BC 7687 controllers are used when it
is necessary to add to any transmitter the display, control,
alarm and the automatic sensor cleaning functions.
The 0-20 mA or 4-20 mA signal from the transmitter is sent
to the instruments who perform the above functions.
In some cases, it is necessary to measure the value before
and after the process. BC 6587 and BC 7687 are able to
display and control the difference of the measurements of
the two transmitters operating with the same full scale.
FeaturesTechnical DataApplications
Specifications
- Display: multi-line graphic
- Input from: 0-20 or 4-20 mA single or differential
- Scale: – 9999 / +9999 with selectable decimal point
- Measuring unit: selectable and 4 digit configurable
- 2 set-point with min/max function, hysteresys and delay time programmable
- Analog output: 0-20 or 4-20 mA isolated for PID regulation or measure transmission
- Min/max alarm relay, activate/deactivate function selectable
- Parameters configuration on two levels with access code selected by the operator
- Two logic digital input for hold or alarm function, selectable
- Power supply: 85/264 Vac – 50/60 Hz, 5 VA
- Protection: IP 66
- Dimensions: 256x230x89 mm
- Registered design: 002564666-002
Inputs: | 4-20 mA, 0-20 mA active or passive single or differentia |
Power supply for passive transmitters: | 24Vdc (50 mA max) |
Zero: | ± 10 % |
Sensitivity: | 12.5 % ÷ 250 % |
Resolution: | 1 digit |
Accuracy: | 0.2 % |
Repeatability: | 0.1 % |
Non-linearity: | 0.1 % |
Dual filter software: | 0.4 ÷ 50.0 seconds for small and large variations |
Dual analog output: | 0-20 mA / 4-20 mA Rmax 600 Ω |
Dual set points HI/LO: | ON/OFF – PID – PFM – PWM, SPST relays |
Hysteresis: | 0 ÷ 1.40 pH, 0 ÷ 200 mV |
Delay: | 0 ÷ 100.0 seconds |
Alarm: | SPDT relay with delay 0 ÷ 100.0 seconds |
Cleaning function: | off / autoclean / manual, relay SPDT repetition time 0.1 ÷ 100.0 hours cleaning time 1.0 ÷ 60.0 seconds holding time 0.0 ÷20.0 minutes |
SPST and SPDT relay contacts: | 220V – 5 A resistive load |
Operating temperature: | -10 ÷ 60 °C |
Humidity: | 95% without condensation |
Power supply: | 85 ÷ 264Vac – 50/60 Hz 9 ÷ 36Vdc, 12 ÷ 24Vac (option 091.42x |
Terminal blocks: | removable |
Weight: | 1360 g (PH 6587) 450 g (PH 7687) |
Enclosure: | ABS, IP 65 protection (BC7687) Metallic, IP 65 front panel only (BC 7687) |
Dimensions: | 256x230x89 mm (BC 6587) 98x98x104 mm, 90x90x95 mm panel cutout (BC 7687) |
EMC/RFI conformity: | EN 61326 |
Registered design: | 002564666-002 (BC 6587) 002564666-003 (BC 7687) |