TriOxmatic® 702 IQ

Universal oxygen for measuring and controlling oxygen input in the biological sewage treatment process in wastewater treatment plants.

Digital electro-chemical IQ sensors for dissolved oxygen, connectable to the IQ SENSOR NET TriOxmatic® IQ: Reliable and proven digital electrochemical oxygen sensors with 3 electrode system (ECDO) for precise and accurate measurements:

•Low investment costs

•No running in, no long-term drift - stable from the beginning to the end

•Self-diagnosis system SensReg/SensLeck by means of 3 electrode system

The electrochemical sensors are known for their high accuracy - from the beginning. Their Teflon membrane makes them extremely insensitive to biological deposits. Therefore, in most cases, you will not need an additional cleaning unit.

Also, the membrane - just like the electrolyte consumption - is monitored continuously. Our self-diagnosis system SensLeck and SensReg show occurring errors automatically. The seawater model is optimized for the use in special media: All wetted parts consist of titanium and plastic and are therefore extremely corrosion-resistant. Furthermore, if you want, you will find a sensor with faster response time or for the measurement of trace oxygen.
Technical DataDownload
Model TriOxmatic®700 IQ TriOxmatic®700 IQ SW* TriOxmatic®701 IQ TriOxmatic®702 IQ
Order No. 201640 201641 201644 201646
* SW: Sensor as sea water model (with plastic arming (POM))
Measuring method Electrochemical
Measuring range (25 °C)
O2 concentration 0.0 … 60.0 mg/l 0.00 … 20.00 mg/l
0.0 … 60.0 mg/l
0 … 2000 µg/l
0.00 … 10.00 mg/l
O2 saturation 0 … 600% 0.0 … 200.0%
0 … 600%
0 … 110%
Resolution
O2 concentration 0.1 mg/l 0.01 mg/l
0.1 mg/l
0.001 mg/l
0.01 mg/l
O2 saturation 1% 0.1%
1%
0.1%
Response time at 25 °C t90: 180 s t90: 30 s
t99: 90 s
t90: 30 s
t99: 110 s
Minimum flow rate 0.05 m/s 0.23 m/s 0.3 m/s
SensCheck SensLeck
SensReg
SensReg SensLeck
SensReg

SensReg
Temp. measurement Integrated NTC, 23 °F … 140 °F (-5 °C … +60 °C) ± 0.5 °C
Temp. compensation 32 °F … 140 °F (0 °C … +60 °C)
Pressure Resistance 10 bar (incl. sensor connection cable)
Ambient Conditions Operating temperature: 32 °F … 140 °F (0 °C … +60 °C); Storage temperature: 23 °F … 149 °F (-5 °C … +65 °C)
Electrical connections 2-wire shield cable with quick fastener to sensor
Electromagnetic Compatibility EN 61326, Class B, FCC Class A;
Intended for indispensable operation
Certifications CE, cETL, ETL
Mechanical Membrane head assembly, locking cap: POM
Sensor body: V4A stainless steel 1.4571
Protection rating: IP 68
Weight (without cable) Approx. 1.46 lb (660 g) Approx. 2.58 lb (1,170 g) Approx. 1.46 lb (660 g)