TriOxmatic® 702 IQ
Universal oxygen for measuring and controlling oxygen input in the biological sewage treatment process in wastewater treatment plants.
Digital electro-chemical IQ sensors for dissolved oxygen, connectable to the IQ SENSOR NET TriOxmatic® IQ: Reliable and proven digital electrochemical oxygen sensors with 3 electrode system (ECDO) for precise and accurate measurements:
•Low investment costs
•No running in, no long-term drift - stable from the beginning to the end
•Self-diagnosis system SensReg/SensLeck by means of 3 electrode system
The electrochemical sensors are known for their high accuracy - from the beginning. Their Teflon membrane makes them extremely insensitive to biological deposits. Therefore, in most cases, you will not need an additional cleaning unit.
Also, the membrane - just like the electrolyte consumption - is monitored continuously. Our self-diagnosis system SensLeck and SensReg show occurring errors automatically. The seawater model is optimized for the use in special media: All wetted parts consist of titanium and plastic and are therefore extremely corrosion-resistant. Furthermore, if you want, you will find a sensor with faster response time or for the measurement of trace oxygen.Model | TriOxmatic®700 IQ | TriOxmatic®700 IQ SW* | TriOxmatic®701 IQ | TriOxmatic®702 IQ |
Order No. | 201640 | 201641 | 201644 | 201646 |
* SW: Sensor as sea water model (with plastic arming (POM)) | ||||
Measuring method | Electrochemical | |||
Measuring range (25 °C) | ||||
O2 concentration | 0.0 … 60.0 mg/l | 0.00 … 20.00 mg/l 0.0 … 60.0 mg/l |
0 … 2000 µg/l 0.00 … 10.00 mg/l |
|
O2 saturation | 0 … 600% | 0.0 … 200.0% 0 … 600% |
0 … 110% | |
Resolution | ||||
O2 concentration | 0.1 mg/l | 0.01 mg/l 0.1 mg/l |
0.001 mg/l 0.01 mg/l |
|
O2 saturation | 1% | 0.1% 1% |
0.1% | |
Response time at 25 °C | t90: 180 s | t90: 30 s t99: 90 s |
t90: 30 s t99: 110 s |
|
Minimum flow rate | 0.05 m/s | 0.23 m/s | 0.3 m/s | |
SensCheck | SensLeck SensReg |
SensReg | SensLeck SensReg |
— SensReg |
Temp. measurement | Integrated NTC, 23 °F … 140 °F (-5 °C … +60 °C) ± 0.5 °C | |||
Temp. compensation | 32 °F … 140 °F (0 °C … +60 °C) | |||
Pressure Resistance | 10 bar (incl. sensor connection cable) | |||
Ambient Conditions | Operating temperature: 32 °F … 140 °F (0 °C … +60 °C); Storage temperature: 23 °F … 149 °F (-5 °C … +65 °C) | |||
Electrical connections | 2-wire shield cable with quick fastener to sensor | |||
Electromagnetic Compatibility | EN 61326, Class B, FCC Class A; Intended for indispensable operation |
|||
Certifications | CE, cETL, ETL | |||
Mechanical | Membrane head assembly, locking cap: POM Sensor body: V4A stainless steel 1.4571 Protection rating: IP 68 |
|||
Weight (without cable) | Approx. 1.46 lb (660 g) | Approx. 2.58 lb (1,170 g) | Approx. 1.46 lb (660 g) |